Hot water modules for calender rolls, recommended maintenance
Feb 16, 2021
All strainers should be cleaned or blown down including the following:
- Strainer on suction side of pump
- Strainer in fill water line
- Strainer in cooling water supply
- Strainer in steam supply line
In addition, check the pump seal, heater and cooler tube bundle, solenoid valve and steam traps. Check the pump seal for leaks and to see if the seal flush operating. Loosen the seal flush coil at the seal end to determine that water is flowing. Repair a leaking seal or coil. Replace a coil if plugged.
Check the solenoids by seeing if they respond to power on and off and if they allow and stop flow of water, steam or air. Replace any bad coils. Clean or replace sticking valves.
If pneumatic valves with positioners are present, check valve operation by moving the temperature setpoint up and down. The controller should be set with a 4 to 5 °F deadband to prevent unnecessary cycling of the valves.
Check to see that auto air vents are working. Clean or repair as necessary.
Check the pipe lines to see that all insulation is still in place. Replace as necessary.
For more information on calender maintenance, contact your Valmet representative.